The set-up consists of different pressure measurement devices fitted in a pipe line, in which an Orifice is fitted to create the pressure difference. Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line ➢To demonstrate the working of different pressure measuring devices.
➢To measure the pressure and pressure difference by pressure gauge, single column manometer, U-Tube manometer & Inclined tube manometer.
➢Electricity supply: Single Phase, 220 V AC, 50 Hz, 5-15 amp combined socket with earth connection. Earth voltage should be less than 5 volts.
➢Water Supply (Initial fill)
➢Floor Drain required.
➢Floor Area Required: 1.5 m x 0.75 m
➢Mercury (Hg) for manometer (750 gm)
➢Single Well Manometer : Single Tube Type.
➢Differential Manometer : U Tube Type.
➢Sensitive Manometer. : Inclined Tube Type
➢Pressure Gauge. : Bourdon Type
➢Water Circulation : ½ HP Pump, Champion/Standard make.
➢Sump Tank : Capacity 60 Ltrs.
➢Control Panel Comprises of: Standard make On/Off Switch, Mains Indicator, etc.
➢Tanks will be made of Stainless Steel.
➢An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the Apparatus
➢The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint